Description
Aries Class B LCD Display Dental Autoclave Table Top Steam Sterilizer
FEATURES
| Sterilization Class | CLASS B |
| Sterilization Temperature | 121ºC &134ºC |
| Special Program | HIV, HBV long-sterilization program |
| Dry System | Vacuum drying system |
| Display | LCD display with touch keys |
| Testing System | Bowie&Dick Test Vacuum Test Helix Test |
| Control Precision | Temperature: 0.1ºC Pressure: 0.1Kpa |
| Sterilization Data | Built in printer |
| Safety System | Relief valve Hand lock door Pressure or temperature over load protection Alarm system |
| Water Supply System | Build-in water tank easy to clean Cubage: 3.5 or 4L |
| Tray Holder | 5 layers tray holder with 3 trays |
| Chamber | Medical stainless steel 304 Max working pressure:2.3bar Min working pressure: -0.9bar Max temperature: 145ºC |
| Operation Temperature | 5~40ºC |
| Noise | <50db |
| Water consumption in one cycle | 0.16L~0.18L |
PROGRAMS
| Program | Temp. | Pres. | Vacuum Times | Sterilization Time | Drying Time |
| EMERGENCY | 134ºC | 210kPa | 1 | 4 min | 8 min |
| SOLID | 134ºC | 210kPa | 1 | 4 min | 8 min |
| HOLLOW | 134ºC | 210kPa | 3 | 4 min | 10 min |
| SANGUINARY | 134ºC | 210kPa | 3 | 18 min | 10 min |
| SOLID | 121ºC | 110Kpa | 1 | 20 min | 8 min |
| HOLLOW | 121ºC | 1100Kpa | 3 | 20 min | 10 min |
| GLASS | 121ºC | 110Kpa | 1 | 20 min | 8 min |
| TAMPON | 121ºC | 110Kpa | 3 | 30 min | 18 min |
| TEST B&D | 134ºC | 210Kpa | 3 | 3.5 min | 3 min |
| TEST HELIX | 134ºC | 210Kpa | 3 | 3.5 min | 3 min |
| TEST VACUUM | |||||
| USER- DEFINED |
MODEL LIST
| Model | Voltage/Power | Chamber Size | Outside Size | Packing Size | Net Weight |
| ARIES-18 | 220V/1500W | Φ245×360 | 560×450×400 | 660×525×495 | 47 |
| ARIES-23 | 220V/1700W | Φ245×470 | 670×450×400 | 770×530×495 | 53 |
PARTS

Application Field
Dental Clinic, Hospital, First-aid Station, Laboratory, Veterinary hospital, Beauty Salon, Tattoo House,
Application Directive and Standard
| Directive or Standard No. | Directive or Standard Name |
| MDD 93/42/EEC | Medical Device Directive |
| PED 97/23/EC | Pressure Equipment Directive |
| EN 61010-1 | Safety regulations for electrical measuring, controlling and laboratory Devices- Part 1: General requirements |
| EN 61010-2-040: | Safety requirements for electrical equipment for measurement, control and laboratory use -Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
| EN 13060 | Small steam sterilizers |
| EN 61326-1 | Electrical equipment for measurement, control and laboratory use – EMC requirements |
Quality System
| Quality System No. | Quality System Name |
| ISO 9001 | Quality management systems-Requirements |
| ISO 13485 | Medical device-Quality management systems-Requirement for regulatory purposes |